Mining-grade Inhibitor Pump Station BZ-660/16G
The mine-used flame-retardant pump station (hereinafter referred to as the flame-retardant pump) is primarily used for spraying flame-retardant agent solutions and applying flame-retardant aerosols underground in coal mines, helping to prevent spontaneous combustion of coal. When mining single or multi-seam coal seams prone to spontaneous combustion, using flame-retardant solutions for fire prevention—specifically by injecting these solutions into residual coal in mined-out areas—is an effective method to suppress spontaneous combustion of remaining coal.
- Product Description
-
Mining-grade Inhibitor Pump Station BZ-660/16G
Product Features
This device features high flow rate, comprehensive functionality, a rational design, and easy portability.
Features low-fluid protection;
The liquid tank has a large capacity for continuous operation;
The atomization rate can reach over 85%.
A device capable of injecting flame retardants and atomizing them into an aerosol can also function as a smoke-suppression and dust-removal pump; adding a surfactant to the water further enhances its effectiveness.Product Specifications
Product Model
Pressure
Traffic
Power
Voltage
BZ-250/15G
15 MPa
250 L/min
75 kW
660/1140V
BZ-365/15G
15 MPa
365 L/min
110 kW
660/1140V
BZ-500/15G
15 MPa
500 L/min
160 kW
660/1140V
BH-250/16G
16 MPa
250 L/min
75 kW
660/1140V
BZ-660/16G
16 MPa
660 L/min
200 kW
660/1140V
Keyword: